Model |
SMT-005-025SA |
SMT-012- 025SA |
SMT-024- 025SA |
SMT-036- 025SA |
SMT-048- 025SA |
|
output |
DC voltage |
5V |
12V |
24V |
36V |
48V |
Voltage tolerance |
±2% |
±1% |
±1% |
±1% |
±1% |
|
Rated current |
5A |
2.08A |
1.04A |
0.69A |
10.52A |
|
Current range |
0~5A |
0~2.08A |
0~1.04A |
0~0.69A |
0~0.52A |
|
Rated power |
25W |
25W |
25W |
25W |
25W |
|
Ripple&noise |
100mvp-p |
150mvp-p |
150mvp-p |
150mvp-p |
150mvp-p |
|
DCvoltage ADJ.range |
± 10% |
±10% |
±10% |
±10% |
±10% |
|
input |
Voltage range |
100~240Vdc |
||||
frequency |
47~63HZ |
|||||
AC current |
3.2A/115VAC,1.6A/230VAC |
|||||
efficiency |
83% |
83% |
83% |
83% |
83% |
|
Inrush current |
Cold start current 18A/115VAC,36A/230VAC |
|||||
Leakage current |
< 1mA/240VAC |
|||||
protection |
overload |
Rated output power115%~150% start over load protection |
||||
protection type:cutoff output,recovery after restart power |
||||||
Over voltage |
6.8~8.2V |
15.6~17.8V |
18.6~20.8V |
30.6~33.2V |
33.2~35.6V |
|
protection type:hiccup mode,auto-recovery after fault condition is removed |
||||||
----- |
----- |
|||||
----- |
||||||
environment |
Working temp,humidity |
-10°C~+60°C,20%~90%RH |
||||
Storagetemp,humidity |
-20°C~+85°C,10%~95%RH non-condensing |
|||||
Withstand vibration |
10~500HZ,2G 10min/1cycle,period for 60 minutes,each axes |
|||||
safety |
Withstand voltage |
I/P-O/P:2.0KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC |
||||
Isolated resistance |
I/P-O/P,I/P-FG,O/P-FG:100M ohms/500VDC |