240 volt rohs constant current power supply 0-10v dimming driver
85*45*26mm dimension, 100% full load burn-in test, 20 degree~40 degree full load Ambient temp 0-10v dimming driver
Specification
Model |
SMT-035-0700CDH |
SMT-025-0700CD |
SMT-035-0500CD |
SMT-018-0350CD |
||
Output |
DC Current |
700mA |
500mA |
350mA |
||
|
Current Accuracy |
±3% |
||||
|
Voltage Range |
23-35V |
15-25V |
20-35V |
10-18V |
|
|
Rated power |
24W |
17.5W |
17.5W |
6W |
|
Input |
Voltage Range |
100~265VAC |
||||
|
Frequency Range |
47~63HZ |
||||
|
PF(Typ.) |
PF>0.9 |
||||
|
Full Load Efficiency(Typ) |
>86%(110V) >88%(220V) |
>86%(110V) >88%(220V) |
>86%(110V) >88%(220V) |
>86%(110V) >88%(220V) |
|
|
AC Current (Typ.) |
0.104A(110V) 0.106A(220V) |
0.102A(110V) 0.103A(220V) |
0.102A(110V) 0.103A(220V) |
0.101A(110V) 0.103A(220V) |
|
|
Leakage current |
<0.72mA/110VAC / ﹤0.75mA/220VAC |
||||
Protection |
Short Circuit |
Protection type: Hiccup mode, recovers automatically after fault condition is removed |
||||
|
Over Current |
≦1.4*Iout |
||||
|
Over temperature |
100℃±10℃ shut down o/p voltage, re-power on to recover |
||||
Environment |
Working TEMP. |
-40~+50℃ |
||||
|
Working Humidity |
20~95%RH,non-condensing |
||||
|
Storage TEM.,Humidity |
-40~+80℃,10~95%RH |
||||
|
TEMP.coefficient |
±0.03%/℃(0~50℃) |
||||
|
Vibration |
10~500Hz,5G 12min./1 cycle,period for 72min.each along X,Y,Z axes |
||||
Safety&EMC |
Safety standards |
EN61347-1 EN61347-2-13. IP20 |
||||
|
Withstand voltage |
I/P-O/P:3.75KVAC I/P-FG:1.88KVAC O/P-FG:0.5KVAC |
||||
|
Isolation resistance |
I/P-O/P I/P-FG O/P-FG:100MΩ/500VDC/25℃/70%RH |
||||
|
EMC EMISSION |
Compliance to EN55015,EN61000-3-2 (≧50%Load) |
||||
|
EMC IMMUNITY |
Compliance to EN61000-4-2,3,4,5,6,8,11,EN61547,A light industry level |
Features:
- waterproof rate: IP20
- High reliability, Dualiable operation.
- Cooling by nature.
- Protections: Short circuit / Overload / Over voltage / Over temperature
- Current Limit : ±5% rated output current
- Protection type : Constant Voltage limiting type; Shut down o/p voltage, re-power on to recover
- Over Voltage : Shut down and latch off o/p voltage, re-power on to recover
- Over Temperature : 85°C±10°C
What is 0-10v dimming?
0-10 V is one of the simplest and earliest electronic control signaling systems, the control signal is a DC voltage that varies between 0 and 10 volts. The controlled lighting should scale its output so that at 10 V, the controlled light should be at 100% of its output, and at 0 V it should at the lowest possible output.